Laboratory Test Detail

Last Updated: April 18, 2024 @ 9:13 am

76075

Mercury, Urine Quant

Specimen:Collect:
  • Timed Urine in Timed Urine Container
Submit:
  • 8 mL (Min:1 mL) Timed Urine in Trace Element Free Tube. Submit Refrigerated.
Special Handling:
  • Mix collection specimen well before transferring into Trace Element Free Tube.
Rejection Criteria:
  • Urine collected within 72 hours after administration of iodinated or gadolinium-based contrast media.
    Specimens contaminated with blood or fecal material.
    Acid preserved urine.
    Specimens transported in non-trace element free transport tube (with the exception of the original device).
Stability:Ambient: 1 Week(s); Refrigerated: 2 Week(s); Frozen: 12 Month(s); Incubated: Unacceptable
Methodology:
  • Inductively Coupled Plasma Mass Spectrometry
Performed:Mon-Fri
Reported:1-5 Day(s)
CPT Codes:
  • 83825
Interpretive Data:Please see report for interpretive data.

For medical purpose only. Methodology: Inductively Coupled Plasma Mass Spectrometry. If contamination is a concern repeat testing. Questions can be directed to laboratory. Test developed and validated by Interpath Laboratory.
Components:
  • 76072 - MERCURY, URINE
  • 76073 - MERCURY, 24hr
  • 76074 - MERCURY, CRT
  • 76035 - HOURS COLLECTED
  • 76036 - CREATININE, URINE
  • 76037 - CREATININE, 24hr
  • 76038 - TOTAL VOLUME
Print Friendly, PDF & Email

Disclaimer:
It is preferable to locate tests on the website and not rely on printed test information, which may soon be out of date.
Updated test information can only be guaranteed by using this website.