Laboratory Test Detail

Last Updated: April 19, 2024 @ 9:13 am

91111

Glucagon

Specimen:Collect:
  • One Protease Inhibitor Tube
Submit:
  • 1 mL (Min:0.5 mL) Plasma . Submit Frozen. Submit in a Standard Transport Tube.
Special Handling:
  • Separate aliquot required for each frozen test ordered
  • Specimen Preparation: Protease Inhibitor tube contact Client Services at (800) 700-6891. A winged collection set must be used.
    NOT RECOMMENDED: Filling collection tubes directly through a needle/tube-holder assembly increases the risk of chemical reflux back into the vein of the patient. WARNING: Collection tubes are NOT STERILE. Mix Collection tube thoroughly. Separate the plasma from cells within 1 hour of collection by centrifugation. Transfer 1 mL plasma to an ARUP Standard Transport Tube and freeze. (Min: 0.5 mL) Do not submit the collection tube for testing.
Rejection Criteria:
  • Grossly Hemolyzed Samples
Stability:Ambient: Unacceptable; Refrigerated: 2 Day(s); Frozen: 3 Month(s); Incubated: Unacceptable
Methodology:
  • Quantitative Radioimmunoassay
Performed:Tuesday
Reported:4-12 Day(s)
CPT Codes:
  • 82943
Components:
  • 91111 - GLUCAGON
Print Friendly, PDF & Email

Disclaimer:
It is preferable to locate tests on the website and not rely on printed test information, which may soon be out of date.
Updated test information can only be guaranteed by using this website.